Engineered for use in corrosive environments. Ideally suited for transferring acids and alkalies.
| Model | Enclosure | Power | Watt | V.F.D |
| SP-ODP | O.D.P | 115/1/50-60 | 450 | NO |
| SP-ODP-2 | O.D.P | 230/1/50-60 | 450 | NO |
NOTE: V.F.D = Variable Frequency Drive
NOT SUITABLE FOR PUMPING FLAMMABLE OR COMBUSTIBLE LIQUIDS.
Engineered for use in corrosive environments. Ideally suited for transferring acids and alkalies.| Model | Enclosure | Power | Watt | V.F.D |
| SP-280P | O.D.P(IP44) | 115/1/50-60 | 825 | NO |
| SP-280P-V | O.D.P(IP44) | 115/1/50-60 | 825 | YES |
| SP-280P-2 | O.D.P(IP44) | 230/1/50-60 | 825 | NO |
| SP-280P-2-V | O.D.P(IP44) | 230/1/50-60 | 825 | YES |
NOTE: V.F.D = Variable Frequency Drive
NOT SUITABLE FOR PUMPING FLAMMABLE OR COMBUSTIBLE LIQUIDS.

| Model | Enclosure | Power | Watt | V.F.D |
| SP-ENC | TEFC (IP54) | 115/1/50-60 | 825 | NO |
| SP-ENC-V | TEFC (IP54) | 115/1/50-60 | 825 | YES |
| SP-ENC-2 | TEFC (IP54) | 230/1/50-60 | 825 | NO |
| SP-ENC-2-V | TEFC (IP54) | 230/1/50-60 | 825 | YES |
NOTE: V.F.D = Variable Frequency Drive
NOT SUITABLE FOR PUMPING FLAMMABLE OR COMBUSTIBLE LIQUIDS.

| Model | Enclosure | Power | Watt | V.F.D |
| SP-400-2 | EXP | 230/1/50-60 | 825 | NO |
| EEx de IIA T5 EN50014 | ||||
| 96D.119 509 EN 50018 |
NOTE: V.F.D = Variable Frequency Drive
SEE WARNING AT BOTTOM OF PAGE
Engineered for use in heavily corrosive environments or when aggressive fumes are present.Ideally suited for transferring flammable / combustible liquids.| Model | Consumption | Max. Inlet Pressure |
Ouput |
| SP-A2 | 28 CFM@90 psi | 100 psi | 3/4 hp |
| 13.2L/sec@6.2bar | 6.8 bar | 560w |
SEE WARNING AT BOTTOM OF PAGE
WARNING: Pumping of flammables or combustible liquids can generate a static electric discharge, causing fire or explosion resulting in injury or death. Read and understand operating instructions before starting this unit. Follow all federal, state and local safety codes including NFPA 30 - NFPA77. Prior to connecting to air supply, install bond and ground wires and check continuity of each wire. A meter reading of one ohm or less is required for safe liquid transfer. Use only metallic drum, receiving vessel and metallic pump (SP-SS) when pumping flammables. Air motors are not recognized under any current Underwriter’s Laboratory listing program. Consult a qualified engineer for suitability for use in a hazardous area or on flammables.